BUILT TO LAST, EASY TO INSTALL AND SERVICE:
- One-piece, standard efficiency electric cooling with a low profile, prewired, tested, and charged at the factory.
- Field convertible from vertical to horizontal airflow on all models. No special kit required on 036 - 150 models. Field accessory supply duct kit required for 180 size model only.
- Full perimeter base rail with built-in rigging adapters and fork truck slots.
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection.
- Fully insulated cabinet.
- Single-stage or two stage cooling capacity control.
- Single or dual scroll compressor with internal line-break overload protection.
- All units have high and low pressure switches.
- Two inch disposable fiberglass type return air filters in dedicated rack with tool-less filter access door.
- Refrigerant circuits contain a liquid line filter drier to trap dirt and moisture.
- Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes
- Newly-designed indoor refrigerant header for easier maintenance and replacement.
- Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.
- Belt drive evaporator-fan motor and pulley combinations available to meet any application.
- Access panels with easy grip handles provide quick and easy access to the blower and blower motor, control box, and compressor.
- "No-strip" screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit's metal.
- Newly designed terminal board facilitates simple safety circuit troubleshooting and simplified control box arrangement.
- Outdoor temperature cooling operation range up to 115°F (46°C) and down to 40°F ( 4°C ) using winter start kit.
- Fixed orifice metering devices on all models to precisely control refrigerant flow.
- Large, laminated control wiring and power wiring drawings are affixed to unit to make troubleshooting easy.
- Standard, medium and high static fan motor options available.
- Capable of thru-the-base or thru-the-curb electrical routing.
- Single point electrical connections.
- 5 Year limited warranty on compressor
- 5 Year limited warranty on electric heater parts
- 1 Year limited warranty on parts
Documents
picture_as_pdf installation instructions
picture_as_pdf warranty document
picture_as_pdf specification sheet
Features and Specification
ERP ID | 290483 |
---|---|
Weight | 607.000000 |
Length | 74.375000 |
Locked Rotor Amps | 62, 66 |
IEER | 11.4 |
Maximum Fuse Size | 20, 25, 40, 45 |
Height | 41.375000 |
Filter Size | 16" x 16" x 2" |
Minimum Circuit Amps | 25, 38, 42 |
Number of Fan Blades | 1 |
UL Listed | Yes |
Refrigerant | R-410a |
Tonnage | 6 |
Stage | Single |
Sound Level (dBA) | 78 |
UOM | EA |
Rated Load Amps | 19, 8.2 |
OPT Code | 1PRAS072L0AA0AAA |
Warranty Offered | Yes |
Phase | Three |
Width | 46.750000 |
Voltage | 460 VAC |
UPC | See Optical |
Package Weight | 645.000000 |
Product Family | RAS |
Certifications | AHRI Certified, ARI Standard |
Equipment Type | Straight Cool |
Brand | Tempstar |
Blower Motor RPM | 1073, 1073-1457 |
Blower Motor HP | 2 2/5 BHP |
Energy Star Rated | Yes |
Air Flow | Convertible |
Cycle/Hertz | 60 Hz |
Circuit Breaker - Max Amps | 20, 25, 40, 45 |
EER | 11.2 |
Drive Type | Belt |
Drain Connection Size | 3/4" |
Drain Connections | 1 |
Cubic Measurement | 83.253600 |
Condenser Motor HP | 1/4 HP |
Compressor | Scroll |
Circuit Breaker - Min Amps | 14, 25, 38, 42 |
Cooling Capacity | 70000 |